What Structural Peer Review Now Covers
Los Angeles, San Francisco and New York now require review panels that reach beyond structure into geotechnical work, ground motions and wind. None of the documents measures how long that takes.
In brief
Los Angeles reissued its structural peer review protocol effective January 1, 2026, and read with San Francisco, New York and Florida rules it shows review reaching more disciplines and building types. None of these documents measures how much longer review takes.
Read transcript
Voice 1: Structural peer review. More cities require it, for more building types, with more people in the room. That is what this analysis documents.
Voice 2: Start with Los Angeles. The building department reissued its peer review protocol effective January 1st, 2026. It requires a panel with a structural engineer and a geotechnical engineer.
Voice 1: And for buildings over 40 stories, or unusual systems, it adds a university professor.
Voice 2: The panel has to issue separate acceptance letters. One for the design criteria, one for the ground motions, one for the final design. Three sign-offs.
Voice 1: Other cities set the trigger by height. San Francisco typically requires review at 240 feet. New York requires it above 600 feet, and added geotechnical and wind tunnel reports with its 2022 code.
Voice 2: Here is the detail I did not expect. Who hires the reviewer varies a lot.
Voice 1: In Los Angeles the owner pays, and the project team finalizes a panel from the department's roster. In San Francisco, the department selects and pays.
Voice 2: And New York requires a reviewer with no financial interest in the project. That affects how independent the reviewer really is.
Voice 1: Does more review mean shared liability?
Voice 2: No. The tall building guidelines say the engineer of record remains solely responsible for the construction documents.
Voice 1: And review fails. The article gives two cases. The pedestrian bridge at Florida International University collapsed in March 2018 and killed six people. Federal investigators found its peer review was inadequate and did not detect the designer's calculation errors.
Voice 2: The second is Champlain Towers South. Federal technical findings from June 2026 describe severe and widespread departures from the codes in force when it was designed. The recommendations are still to come.
Voice 1: One honest limit. The headline was changed, because the evidence is about breadth. None of these documents reports how long review takes, or what it costs.
Voice 2: More disciplines and more sign-offs plausibly take more time. But that is an inference, and the piece labels it as one.
Voice 1: The full piece, with sources, is at fieldletterpress.com.

The Los Angeles Department of Building and Safety reissued its structural peer review protocol as Information Bulletin P/BC 2026-147, effective January 1, 2026, superseding the 2023 edition1. The bulletin requires a panel with a structural engineer and a geotechnical engineer, and adds a university professor for buildings over 40 stories, unusual systems or atypical materials1. The owner pays for the panel separately from plan check fees, and the panel must issue separate acceptance letters for the design criteria, the ground motions and the final design1.
Read alongside the equivalent documents in San Francisco, New York and Florida, the bulletin shows peer review reaching into more disciplines and more building types. What the written record does not show is how much longer review takes, because none of these documents measures it.
Los Angeles requires the panel for performance-based designs, nonlinear response history procedures, seismic isolation or damping systems, and alternative lateral force procedures. The listed scope runs from earthquake hazard determination and ground motion characterization through modeling, acceptance criteria, drawings and specifications, to the locations of seismographs and structural monitoring equipment1. The record of the review is a comment log with the engineer of record's written responses1.
San Francisco's Administrative Bulletin AB-082, issued November 21, 2018 and updated January 1, 2023 for code references, names four review disciplines: structural, geotechnical, site-specific seismic hazard, and ground motion selection and scaling2. Review is triggered by ASCE 7-16 Sections 16.5, 17.7 and 18.5, which cover response history analysis, isolation and damping. Buildings 240 feet or taller typically get review in three disciplines even when designed prescriptively, and those on the softest soils or in liquefaction zones need two geotechnical reviewers unless piles or piers reach bedrock2. The department selects and pays the reviewers2.
The Pacific Earthquake Engineering Research Center's Tall Buildings Initiative guidelines, Version 2.03 of 2017, set out a similar structure. Chapter 8 calls for reviewers acceptable to the building authority with expertise in seismic hazard, structural behavior and nonlinear analysis software, and sets a nine-item minimum scope from the basis of design through drawings, specifications and quality assurance3. The second edition's summary says project teams had extended the method beyond regular core-wall buildings in Risk Category II to other systems, irregular structures, multiple towers on one podium and higher risk categories3.
New York's triggers are geometric. Buildings Bulletin 2015-031 lists the conditions under what was then Building Code Section 1617.2, including height over 600 feet, gross floor area over 1,000,000 square feet, an aspect ratio of seven or more, and nonlinear time history analysis4. The 2022 code carries those triggers in Section 1618.210. The Department of Buildings will approve construction documents only with a reviewer's report that accepts code compliance without exceptions4. The department's filing guide to the 2022 code adds a geotechnical peer review report under Section 1818 and a wind tunnel test peer review report under Section 1609.1.65.
| City | What triggers review | Who selects and pays |
|---|---|---|
| Los Angeles | Performance-based designs, nonlinear response history procedures, seismic isolation or damping, alternative lateral force procedures | Project team finalizes a panel from the department's recommended roster; the owner pays |
| San Francisco | Response history analysis, isolation and damping; buildings 240 feet or taller typically reviewed in three disciplines | The department selects and pays |
| New York | Height over 600 feet, gross floor area over 1,000,000 square feet, aspect ratio of seven or more, nonlinear time history analysis | Reviewer acceptable to the applicant of record, with no financial interest in the project |
Summarized from each department's published bulletin. Triggers are abbreviated; the bulletins list further conditions. Source: Los Angeles Department of Building and Safety; San Francisco Department of Building Inspection; New York City Department of Buildings.
Florida's requirements are inspection regimes, which is a different thing. Section 553.79(5) requires a special inspector on threshold buildings, selected and paid by the fee owner but responsible to the enforcement agency, working to a structural inspection plan prepared by the engineer or architect of record6. Section 553.899, enacted in 2022 after the Surfside collapse and amended in 2023, 2024 and 2025, requires a milestone inspection of condominium and cooperative buildings of three or more habitable stories by December 31 of the year the building turns 30, and every 10 years after that7. Local agencies may set the trigger at 25 years7.
Breadth is documented. Duration is not.
The evidence is about breadth. San Francisco names geotechnical and ground motion reviewers alongside the structural one, New York added geotechnical and wind tunnel reports with its 2022 code, Los Angeles lists monitoring locations and a third panelist, and the Tall Buildings Initiative's second edition records the method's spread to more building types1235. A review with more disciplines and more sign-offs plausibly takes more time, but that is an inference. None of these documents reports durations, hours or fees.
Who hires the reviewer varies from city to city, and with it the reviewer's independence from the project. Los Angeles has the project team finalize a panel from the department's recommended roster and the owner pay1. San Francisco's department selects and pays2. New York requires a reviewer acceptable to the applicant of record who has no financial interest in the project4.
What review does not do
More review has not meant shared liability. The Tall Buildings Initiative guidelines state that the engineer of record remains solely responsible for the construction documents3, and Florida's statute says the special inspector does not stand in for the building official or the engineer of record6.
Review can also fail. The National Transportation Safety Board found that the peer review of the Florida International University pedestrian bridge, which collapsed on March 15, 2018 and killed six people, was inadequate and did not detect the designer's calculation errors8. NIST's June 22, 2026 technical findings on Champlain Towers South describe severe and widespread departures from the codes in force when the building was designed, and the agency's recommendations are still to come in a final report with no announced date9.
NIST's final report on Champlain Towers South, which the agency says will carry recommendations on codes, standards and practices, has no announced release date. San Francisco's AB-082 was last updated January 1, 2023 and is still keyed to ASCE 7-16 section numbers, and the Florida Legislature has amended Section 553.899 in 2023, 2024 and 2025. Any of the three could widen the scope again.
Know someone who should read this?
Send it to the engineer of record you work with most. Practical pieces like this one travel fastest from one practitioner to another.
Get the next one in your inbox
The Brief on Tuesdays and Field Note on Fridays, with Engineering stories first. About five minutes each.
Read a sample issue before you sign up. One click to unsubscribe. Privacy notice. Edited by a team with more than 90 years combined in AEC business development, civil engineering and construction surety.
Updated November 15, 2026. This piece is now credited to the Engineering Desk rather than a named desk byline, a short summary was added at the top, and the publication date was corrected to November 14, 2026, the day it first appeared on this site. Standards and corrections.
Sources
- Information Bulletin P/BC 2026-147, Structural/Seismic Peer Review ProtocolLos Angeles Department of Building and Safety · January 1, 2026 · primary source
- Administrative Bulletin AB-082, Guidelines and Procedures for Structural, Geotechnical, and Seismic Hazard Engineering Design ReviewSan Francisco Department of Building Inspection · January 1, 2023 · primary source
- Guidelines for Performance-Based Seismic Design of Tall Buildings, Version 2.03, PEER Report 2017/06Pacific Earthquake Engineering Research Center · May 2017 · primary source · read in part
- Buildings Bulletin 2015-031, structural peer review under BC Section 1617New York City Department of Buildings · November 4, 2015 · primary source
- 2022 Construction Codes changes in DOB NOW (filing guide)New York City Department of Buildings · date not shown · primary source
- Florida Statutes Section 553.79, Permits; applications; issuance; inspections (2026)Florida Legislature · 2026 · primary source
- Florida Statutes Section 553.899, Mandatory structural inspections for condominium and cooperative buildings (2026)Florida Senate · 2026 · primary source
- Pedestrian Bridge Collapse Over SW 8th Street, Miami, Florida, HWY18MH009 (report HAR-19-02)National Transportation Safety Board · date not shown · primary source · read in part
- NIST Releases Technical Findings on What Caused the 2021 Partial Collapse of Champlain Towers SouthNational Institute of Standards and Technology · June 22, 2026 · primary source
- 2022 New York City Building Code, Chapter 16, Structural Design (Section 1618, Structural Peer Review)New York City Department of Buildings · 2022 · primary source · read in part
Credited to the Field Letter Press Engineering Desk, a desk credit rather than a named reporter. This piece was researched and drafted with AI assistance, and each claim was checked against the sources listed above by a separate reviewer. Field Letter Press did not interview anyone for it. How we work · Report an error