In brief

Keeping an old building can save carbon, but the existing-building code decides whether the frame can stay as it is. A change of occupancy or added gravity load can trigger new-building structural requirements, so settle the code path and the testing program before promising the carbon savings.

Listen · The Read-Back · 2:16
Read transcript

Voice 1: Adaptive reuse. Everyone knows the carbon argument for keeping an old building. This piece, from the architecture desk, says the argument only gets you to the front door.

Voice 2: Right. The carbon case is real. A National Trust study from 2011 found a new building that is 30% more efficient than an average existing one can take 10 to 80 years to pay back the climate cost of its own construction.

Voice 1: So you keep the frame.

Voice 2: You decide to keep the frame. Then the existing-building code starts asking the structural engineer questions. The article uses Seattle's 2021 code to show the mechanics. Raise the gravity load on an existing element by more than 5%, and that element has to meet the loads for a new structure.

Voice 1: And for lateral elements?

Voice 2: A 10% allowance on the demand to capacity ratio, counting earlier work. Beyond that, you are into seismic evaluation.

Voice 1: The sharper trigger is change of occupancy, though. Offices to housing, warehouse to almost anything.

Voice 2: Yes. Move the building into a higher risk category, and the model code text wanted full new-building seismic forces. That is where retention gets expensive.

Voice 1: Here is the line I keep coming back to. An owner who wants a low investigation budget is choosing a more conservative analysis.

Voice 2: Because under the concrete assessment code, the more you test and document, the better the knowledge factor in your analysis. Skip the testing, and the engineer has to assume less. That can mean more strengthening, and more new material.

Voice 1: Which eats the carbon savings you started with.

Voice 2: The National Trust's own study had one case like that. A warehouse converted to apartments never reached climate breakeven, mostly because of the new material it needed.

Voice 1: The piece is candid about what it could not establish. Nobody in these documents says how often a change of use forces a full seismic upgrade, or how much carbon the strengthening adds back.

Voice 2: So the practical advice is about sequence. Settle the code path and the testing program before anyone promises the carbon savings.

Voice 1: And check which edition your jurisdiction has adopted. The full piece, with sources, is at fieldletterpress.com.

Episode 26
Curved concrete facade with ribbon windows
Photo: Markus Winkler / Pexels. Stock photograph used for illustration. It does not show a project or place named in this article.

The argument for keeping an old building usually starts with carbon. A 2011 life-cycle study by the National Trust for Historic Preservation found that a new building 30% more efficient than an average existing one can still take 10 to 80 years to offset the climate impact of its own construction1.

That finding gets a project as far as the decision to keep the frame. From there the existing-building code takes over, and it asks the structural engineer a short list of specific questions: how much load the new use adds, whether the building moves into a higher risk category, and what level of seismic force it must now resist34. The answers turn on a few numeric triggers and on how much anyone can document about materials that were often never recorded on the drawings37. They are worth settling, along with the testing program, before the carbon savings are promised.

The carbon case is well documented, and it has limits. The National Trust study compared reuse and new construction over a 75-year period in Portland, Phoenix, Chicago and Atlanta, and reported that reuse saved roughly 4% to 46% in environmental impact against a new building of the same energy performance1. One case went the other way: the warehouse-to-multifamily conversion never reached climate breakeven against the efficient new building, which the report attributes mainly to the quantity and type of new material the conversion needed1.

Historic England's evidence review points the same direction and is more specific about where the benefit sits. It cites Hasik and colleagues (2019) as finding, in a life-cycle assessment of one adaptive reuse project, that renovation avoided 53% to 75% of the impacts of new construction, with retention of the main structure and envelope mattering most2. FLP has not checked those figures against the original studies.

What the code asks of an old frame

Seattle's 2021 Existing Building Code, which is built on the International Existing Building Code, shows how those questions work in practice. An alteration that raises the design gravity load on an existing element by more than 5% requires that element to carry the building-code load for new structures3. An existing lateral element may stay unaltered if its demand-capacity ratio rises by no more than 10%, counting the cumulative effect of earlier work3. Where the code permits reduced seismic forces, one option is 75% of the forces prescribed for new buildings; another is evaluation under ASCE 41, the standard for seismic evaluation and retrofit, against performance objectives tabulated by risk category3.

Table
Three thresholds in Seattle's 2021 Existing Building Code
Three thresholds in Seattle's 2021 Existing Building Code
ConditionThresholdConsequence
Added gravity load on an existing elementMore than 5%Element must carry the load required of a new structure
Demand-capacity ratio of an existing lateral elementRise of no more than 10%, counting earlier workElement may stay unaltered
Reduced seismic forces, where the code permits them75% of new-building forcesOne of the permitted options; evaluation under ASCE 41 is another

Section numbers and values are from Seattle's 2021 code, which is built on the International Existing Building Code. Other jurisdictions amend them. Source: City of Seattle, Department of Construction and Inspections.

A change of occupancy is the sharper trigger. The model text that Seattle prints as deleted in its Chapter 10 required a building moved to a higher risk category to meet the new-building seismic provisions using full seismic forces, with exceptions that included a new occupancy under 10% of the building area4. A 2024 International Code Council presentation to California building officials describes the same structure for the California Existing Building Code: new-occupancy live loads, a 5% gravity and 10% lateral allowance, and full seismic forces on a move to a higher risk category5. Seattle replaced the model exceptions with its own rule, which keeps the model text's trigger for a change from storage or utility occupancy to any other use and accepts an ASCE 41 Tier 3 evaluation as meeting the seismic requirement3.

ASCE 41 was reissued as ASCE/SEI 41-23. According to ASCE, the standard uses three tiers, each more engineering-intensive and less conservative than the last, and the 2023 edition now points to AISC and ACI documents for steel and concrete provisions8. For concrete, the ACI document is ACI CODE-369.1-22, under which in-place material properties come from drawings and specifications, testing is required when those documents are inadequate, and the extent of testing and condition assessment sets the knowledge factor applied in the analysis7. Its commentary notes that concrete strength in older construction was often below 3000 psi and rarely shown on drawings7.

Testing, and who pays for it

The carbon studies and the code measure different things, and the gap between them is where projects stall. The life-cycle comparisons assume the retained structure is usable. The code decides how much of it is, element by element, and the answer depends on the new use more than on the age of the frame13. The National Trust's own warehouse-to-multifamily result shows how new material can cancel the benefit1.

The owner's interest and the engineer's diverge on testing. Under ACI 369.1 the knowledge factor follows the extent of testing and condition assessment, and original construction records can reduce the in-place testing needed7. An owner who wants a low investigation budget is therefore choosing a more conservative analysis. That can mean more strengthening and more new material. ACI CODE-562-25, the assessment and repair code written to work with the IEBC or as a stand-alone code, has a full chapter on assessment, material properties and load testing and a separate chapter on reinforcement that covers historical reinforcing bars6.

Two things remain unestablished in the documents reviewed for this article. None quantifies how often a change of occupancy in practice forces a full seismic upgrade, and none states how much embodied carbon typical strengthening adds back. The 2024 IEBC text on the ICC's site could not be opened, so the section numbers above come from Seattle's 2021 code and should be checked against the edition a jurisdiction has adopted.

Three adoption questions will shape the answer on any given project: which IEBC edition, and which local amendments to its change-of-occupancy section, the jurisdiction uses; whether the building official accepts ASCE/SEI 41-23 or still references the 2017 edition, to which ACI CODE-369.1-22 is keyed; and whether the state or city has adopted ACI CODE-562-25 for the assessment and repair of existing concrete.

Know someone who should read this?

Send it to the architect or owner’s rep on your next project. Practical pieces like this one travel fastest from one practitioner to another.

Free · Tuesday & Friday

Get the next one in your inbox

The Brief on Tuesdays and Field Note on Fridays, with Architecture & Design stories first. About five minutes each.

Read a sample issue before you sign up. One click to unsubscribe. Privacy notice. Edited by a team with more than 90 years combined in AEC business development, civil engineering and construction surety.

Updated November 15, 2026. This piece is now credited to the Architecture & Design Desk rather than a named desk byline, a short summary was added at the top, and the publication date was corrected to November 14, 2026, the day it first appeared on this site. Standards and corrections.

Sources

  1. The Greenest Building: Quantifying the Environmental Value of Building ReuseNational Trust for Historic Preservation, Preservation Green Lab · 2011 · primary source · read in part
  2. Heritage, Buildings and Embodied Carbon (Heritage Counts: Heritage and the Environment)Historic England · date not shown · secondary source
  3. 2021 Seattle Existing Building Code, Chapter 3: Provisions for All Compliance MethodsCity of Seattle, Department of Construction and Inspections · 2021 · primary source
  4. 2021 Seattle Existing Building Code, Chapter 10: Change of OccupancyCity of Seattle, Department of Construction and Inspections · 2021 · primary source
  5. Applying new provisions of the California Existing Building Code (presentation by Sandra Hyde, International Code Council, CALBO 2024 annual business meeting)California Building Officials / International Code Council · 2024 · secondary source
  6. ACI CODE-562-25: Assessment, Repair, and Rehabilitation of Existing Concrete Structures, Code Requirements and Commentary (preview)American Concrete Institute · January 2025 · primary source · read in part
  7. ACI CODE-369.1-22: Seismic Evaluation and Retrofit of Existing Concrete Buildings, Code and Commentary (preview)American Concrete Institute · January 2023 · primary source · read in part
  8. ASCE 41-23 provides significant updates to requirements for seismic evaluation and retrofit of existing buildingsAmerican Society of Civil Engineers, Civil Engineering Source · November 30, 2023 · secondary source

Credited to the Field Letter Press Architecture & Design Desk, a desk credit rather than a named reporter. This piece was researched and drafted with AI assistance, and each claim was checked against the sources listed above by a separate reviewer. Field Letter Press did not interview anyone for it. How we work · Report an error

Keep reading