What Clients Mean When They Ask for “Timeless”
Timeless is not something a specification can require. A design service life in years, component lives and a signed maintenance commitment are.
In brief
A specification cannot require a building to be timeless. It can require a design service life in years, component lives and a maintenance commitment the owner signs, each of which can be written into the contract and checked at substitution and close-out.
Read transcript
Voice 1: A client says, I want this building to be timeless. What do you write in the specification?
Voice 2: Nothing, because timeless is not a property you can specify. That is the starting point of this explainer from the architecture desk.
Voice 1: So what can you specify?
Voice 2: A design service life in years. Canada's durability standard, C.S.A. S 478, requires that the predicted service life of a building meet a design service life agreed between the designer and the owner. That is according to a 2025 review of the standard.
Voice 1: And one number for the whole building is not enough.
Voice 2: No. The standard ties each element's life to the consequence of its failure. If failure means moderate repair cost, the element needs at least 20% of the building's design life. High repair cost, 50%. If failure threatens safety, it has to last the full life.
Voice 1: Which matters, because components wear out at very different rates. A federal housing study collected roof covering lives of 12 to 25 years, and slate roofing at 50 to 100.
Voice 2: Here is the part I found most interesting. Why do buildings actually come down?
Voice 1: The demolition survey.
Voice 2: A 2004 survey of 227 buildings demolished in Minneapolis and Saint Paul. A specific problem with a structural or other material was a reason for only 3.5% of them. Eight buildings. Area redevelopment was cited for almost 35%.
Voice 1: So a client asking for permanence is usually asking for two things. Physical durability, which the standards address. And continued usefulness, which they do not.
Voice 2: And the article flags that this is one metro area over four years, so it shows a direction more than a ratio.
Voice 1: There is also a paperwork lesson. The Ontario architects' practice tip says a client can accept less durable components, as long as the choice is discussed and recorded, with a signed acknowledgement.
Voice 2: That protects the architect. It also makes the owner's maintenance promise part of the durability claim.
Voice 1: So the takeaway. Ask the owner for a number of years and a maintenance commitment, then specify each envelope component against it. And give adaptability equal weight.
Voice 2: The full piece, with sources, is at fieldletterpress.com.

Clients ask for buildings that will last, and the word they often use is timeless. A specification cannot require that. It can require a number of years, a list of components with their own shorter lives, and a maintenance commitment the owner signs, and each of those can be written into the contract documents and checked at substitution and close-out34.
The vocabulary for doing so already exists. CSA S478:19, Canada's durability standard for buildings, requires that the predicted service life of a building meet a design service life agreed between designer and owner, according to a 2025 review of the standard published by IIBEC3. ISO 15686-1:2011, confirmed by ISO in 2020 and now listed for revision, sets a framework for service life planning across a building's whole life cycle1. The research on why buildings are actually demolished suggests that adaptability deserves as much attention as either5.
The Ontario Association of Architects' practice tip on durability separates four terms: durability, design service life, predicted service life and service life. Design service life is set by the designer according to the owner's expectations and adjusted for the maintenance the owner commits to4. CSA Group describes S478:19 as a second edition, replacing a 1995 guideline, that sets minimum requirements and compliance criteria for design service life, predicted service life, construction processes, quality management and an operation, maintenance and inspection program2. Mechanical and electrical systems are outside its scope, as are finishes that do no performance work2.
The standard ties the life of each component to the consequence of its failure. In Gerald Genge's account for IIBEC, S478 assigns a building a design-life category, with long-life buildings such as residential and mid- and high-rise offices at 50 to 99 years, and then sets minimum element life by failure category3. An element whose failure reduces resistance or brings moderate repair cost needs at least 20% of the building's design life. One whose failure means loss of resistance or high repair cost needs 50%. Where failure threatens health and safety or repair cost would be prohibitive, the element must last the full design life3. Service life may be predicted from documented field performance, modelling or both, and novel elements in new environments need laboratory or field testing3. The structural side has its own convention: Designing Buildings, a UK industry wiki, reported in 2022 that BS EN 1990 gives an indicative design working life of 50 years for ordinary building structures and 100 years for monumental buildings and bridges7.
Component data show why a single number for the whole building is not enough. A 2002 NIST and HUD baseline study of US housing collected published service lives that range from 12 to 25 years for roof coverings and 20 to 25 years for windows in the ASTM source it used, up to 50 to 100 years for slate roofing6. The authors cautioned that the ranges come from different sources and assume components perform independently, when in practice moisture trouble in one can shorten the life of another6.
Why buildings actually come down
The research on why buildings come down points away from materials altogether. Jennifer O'Connor's 2004 survey for Forintek covered 227 buildings demolished in Minneapolis and St. Paul between 2000 and 20035. Area redevelopment was cited for 34.8% of them and a specific problem with a structural or other material or system for 3.5%, eight buildings5. Of 70 buildings demolished for physical condition, 54 cited lack of maintenance5. O'Connor concluded that structural material had no meaningful relationship to service life and that design should concentrate on flexibility for future change and on deconstruction5.
A client asking for permanence is usually asking for two different things. One is physical durability, which S478 and ISO 15686 address directly. The other is continued usefulness, which the demolition records suggest is the more common reason a building is lost and which neither a material standard nor a longer design life secures135. The survey is one metropolitan area over four years, and its text and figures disagree on one category (the text says about 38% cited physical condition; the figure shows 30.8%), so it supports a direction more than a ratio5.
What the owner signs
Durable components cost more at bid and less in service, so the interests at the table do not line up, and the OAA document says plainly that a client may accept less durable components with more frequent replacement, provided the choice is discussed and recorded4. It recommends that the architect obtain signed client acknowledgement, review substitutions against predicted service life during bidding, and hand over a maintenance and inspection record at close-out4. That paperwork protects the architect, and it also makes the owner's maintenance promise part of the durability claim.
The legal force of all this is uneven. Ontario's 2024 Building Code cites CSA S478, Durability in buildings, as good practice for assemblies separating dissimilar environments, says designs need not comply with Tables 1 and 2 of that standard, and requires the designer to consider design service life in consultation with the owner8. The OAA's 2020 practice tip, written under the previous code, said the code then cited the 1995 guideline and that a new edition has no legal effect until legislation references it4. Genge wrote in 2025 that S478:19 was not referenced in the National Building Code of Canada or adopted in provincial regulation3. This article relies on CSA's description of the standard and on Genge's summary, not on the standard's clauses, and no published dataset was found that ties warranty terms to observed service life.
Three developments would change the picture: ISO's revision of ISO 15686-1:2011, which its catalogue lists as due; a future edition of the National Building Code of Canada that references CSA S478:19; and the way Ontario building officials apply the 2024 code's requirement that the designer consider design service life in consultation with the owner.
Know someone who should read this?
Send it to the architect or owner’s rep on your next project. Practical pieces like this one travel fastest from one practitioner to another.
Get the next one in your inbox
The Brief on Tuesdays and Field Note on Fridays, with Architecture & Design stories first. About five minutes each.
Read a sample issue before you sign up. One click to unsubscribe. Privacy notice. Edited by a team with more than 90 years combined in AEC business development, civil engineering and construction surety.
Updated November 15, 2026. This piece is now credited to the Architecture & Design Desk rather than a named desk byline, a short summary was added at the top, and the publication date was corrected to November 14, 2026, the day it first appeared on this site. Standards and corrections.
Sources
- ISO 15686-1:2011, Buildings and constructed assets: Service life planning, Part 1: General principles and framework (catalogue entry and abstract)International Organization for Standardization · May 2011 · primary source · read in part
- CSA S478:19, Durability in buildings (product page and scope)CSA Group · 2019 · primary source · read in part
- Achieving Building Enclosure Durability Using CSA S478IIBEC (International Institute of Building Enclosure Consultants) · November 3, 2025 · secondary source
- Practice Tip PT.38, Ontario Building Code Part 5 Environmental Separation: Durability (Version 2.1)Ontario Association of Architects · May 15, 2020 · primary source
- Survey on actual service lives for North American buildingsForintek Canada Corp. (Jennifer O'Connor), hosted by the Canadian Wood Council · October 2004 · primary source
- NISTIR 6870, Baseline Measures for Improving Housing DurabilityNational Institute of Standards and Technology · September 2002 · primary source · read in part
- Design lifeDesigning Buildings · April 27, 2022 · secondary source
- 2024 Building Code Compendium, Division B, Part 5: Environmental SeparationGovernment of Ontario · October 20, 2026 · primary source · read in part
Credited to the Field Letter Press Architecture & Design Desk, a desk credit rather than a named reporter. This piece was researched and drafted with AI assistance, and each claim was checked against the sources listed above by a separate reviewer. Field Letter Press did not interview anyone for it. How we work · Report an error